Just run a twin and earth from the supply side of the existing fcu to the new ones supply side ,and connect both lights to its load side. 30 day money back guarantee. Option 2. Terminals accept 3 x 2. Was to see if any one in the forum could see a problem. com. Assemble with other products into a modular front plate to create a grid. You need the neutral to make the light work but you can take a spur from the socket underneath the desk for a light, you could place a FCU next to socket underneath desk then run cable to light switch and then on to light fitting . 5mm2 T&E. Terminal Capacity. From the incredible Screwfix range of Home & Storage products, Kitchen Designs, Lighting, Paint & Varnish, Painting Accessories. 5mm², 2 x 4mm² or 1 x 6mm² cables. PayPal accepted online. Supplied with four screw cap covers for a sleek profile finish. Coloumb Screwfix Select. touc New Member. The FCU will have a removable bit of plastic for a flex to go into. I always put a FCU outside the room and then a flex outlet in the bathroom but the job i refer to was a right pain in the * too so i opted for the easier option. You made up a rule about no of spurs from one point. Hi all and thanks for taking the time to read this post. Let me repeat post #102. Bazza Screwfix Select. What is your opinion on this workmanship, I think it is shabby and very unprofessional but the FCU is 2 inches away from the side of the boiler and 15cm horizontally away from the the gas cooker hobs and vertically 40cm high from the cookers hobs. I assumed (maybe incorrectly) that what was required above would have been fed off the FCU load as is the cooker hood, so when the FCU switch would be off it would in turn also isolate these new sockets. Screwless Faceplate. You can only spur one double or one single off the ring when you do not have the FCU first. 3/5. The switch at the lower part on the wall underneath the fcu is just a 20A double pole switch that will turn off the supply inside the garage isolating all power from that point. Discussion in 'Electricians' Talk' started by seneca2, Nov 27, 2007. Made from durable, high quality urea with antimicrobial properties. KC DIY New Member. Discussion in 'Electricians' Talk. Hans_25 said: ↑. There should not be any significant heat in the duct. Am adding a 13A FCU/timer indoors to control it, so question is whether to put this before or after the 20A isolator? NB indoor and outdoor interconnects are DC 24V only so so intermediatory. Discussion in 'Electricians' Talk' started by seneca2, Nov 27, 2007. I want to run a spur from the outdoor socket into the shed to power a small wifi camera. It would be ideal if extra sockets could be added as a spur from the cooker socket / switch or from the FCU above the cupboards which only seems to control the cooker socket / switch - e. From the menu that appears, click or tap on the 'Settings Icon' on the top right menu. Order 13A Switched Fused Spur with Neon White at Screwfix. Raised Rounded Profile. 5 T+E thats been spurred directly off the back of another socket and wired to a FCU for a table lamp by the dogs bed in the kitchen, thats. Screwfix Community Forum. 5mm², 2 x 4mm² or 1 x 6mm² cables. Order British General 900 Series 13A Switched Fused Spur & Flex Outlet White at Screwfix. The fittings are each fed by a single 2+e cable which go back to a junction box from which comes, among other things, the 2 gang switch that controls them. Without RCD. 4. My reason for down rating would be that 10mm cable which is what the shower circuit is wired in, is exspensive and a pain to work with but I see your point. Thread by: itisgeorge , Mar 16, 2022 ,. FREE next day delivery available, free collection in 1 minute. After looking at the switch wiring, it looks like it is a double pole switch with a load and supply. Lectrician Screwfix Select. Click & Collect. Wellwisher, Sep 11, 2023. Apple Pay accepted in store. Is it acceptable for a cooker circuit, 40A RCD 10mm T&E, to also feed an FCU which supplies cooker hood 3A. com. This utilises a small transformer that is mounted next to a socket by a TV. Skip to content. FREE next day delivery available, free collection in 1 minute. Supplied with four screw cap covers for a sleek profile finish. That is why the fcu has a 13A fuse. 5mm² overload ? Mr. Order MK Metalclad Plus 13A Switched Metal Clad Fused Spur with White Inserts at Screwfix. there’s no need. 54 Available at SAN MARCOS. Hans_25 said: ↑. Dunno Squash - prefer a plug and socket in that scenario, but hey ho manufacturers instructions and all. 5 from a 2. So my setup ideally will be Ring mains double socket >spurred to > FCU > double. Sku: 01140302 More Options. Teki said: ↑. Screwfix Direct DIY, Paint Supplies: Shop Online at Screwfix Direct Home Improvement for UK Paint Supplies. 5mm2 2 core and earth. 1. Another sensible reply! networkgeeks, Jun 3,. Any questions please ask. Free returns. 0mm cable you have fulfilled all the requirements of the regulations as long as it is okay for volt drop and you have used water-proof glands (CW type). To repeat myself for claritys sake: -. FREE next day delivery available, free collection in 1 minute. Rounded switched fused connection unit. Check for dead. Advantage Federal Credit Union would be delighted to answer any inquiry you might have about your financial affairs, just use the Live Chat option below or choose a phone number based on your inquiry. For joining non-pressure pipes of differing outer diameters and materials. Take a spur off a socket above the worktop as a feed to the new single socket. Run the standard flex in to a standard flex outlet plate which will have a connector block inside it and then run some 1. . 99 Inc Vat. Isolate power at your consumer unit/fusebox using the main switch. You would be better off using a modular system. Delivery 7 days a week. -20°C to 40 °C. I’m fairly sure that you’ve misunderstood the reply from Comlec The OP asked about fitting an FCU to power a light fitting from socket Comlec suggested fitting a S (switched) FCU as that saves fitting a separate light switch -. I therefore understood that it was still classed as within zone 2 because it was easily accessible (I have a feeling I may be wrong though from your comments). Follow the remaining on screen instructions to accept the terms and agreements and. Wellwisher said: ↑. When you think most people typically wire a spur using 2. Was to see if any one in the forum could see a problem. A 13A FCU (Screwfix p/n D15777) or 20A DP Switch (Screwfix p/n D13639)? Secondly, the existing consumer unit is one of the old bakelite ones which has probably been here since the house was built in the 50s. Order LAP 13A Switched Fused Spur Brushed Stainless Steel with White Inserts at Screwfix. 5?) Second plan: seneca Screwfix Select. British General 900 Series 13A Unswitched Passive Fused Spur White (8250P) (57) compare. 3. Apple Pay accepted in store. Screwfix customers rate this product 4. I’ve also had the top cover trimmed down so it can ‘easily’ be removed (2 screws) if. Thus indicating an issue with the switch. CraigMcK Screwfix Select. my question is do i have to have a FCU for the hood? or can i take off the FCU and use a connector block and wire the hood direct? put the connector block in metal back box and put metal cover and use filler and paint. Order MK Metal-Clad Plus 13A Switched Metal Clad Fused Spur & Flex Outlet with White Inserts at Screwfix. Spur off socket to unswitched FCU From unswitched FCU to a switched FCU (needed for functional switching of fly zapper) The load side of SFCU going to the fly zapper and from feed side of SFCU to another SFCU to power outside light. If any earth. At AMOCO, we have financial products and services to fit your needs. I was told by a friend that new regs require fcu`s on all appliances such as dishwashers, washing machines etc. Home Forums > Screwfix Community Forum > Electricians' Talk > 16mm back box for FCU Discussion in ' Electricians' Talk ' started by torquay123 , Nov 6, 2006 . ie. An FCU is not switchgear. spirits are real 2016 Screwfix Select. Delivered by our approved supplier, Find out more. bearing in mind the supply is 6mm cable do you guys have. They even refer to switches as plugs and plugs as switches, sockets as plugs, etc etc. Account Summary Made Better: Lines of Credit, Payment Due Dates, Current and Available Balances, Certificate Maturity Dates and more showing right from the home screen. Once I'd fitted all the new sockets, I temporarily connected the FCU to the double socket to test it (photo below). Can I do any of the following and maintain compliance with the regs? My preferred plan: Connect in an external IP54+ 3A FCU via the (feed or switch?) @ 13A FCU with appropriate cable (1. . com. com. for the cooker hood. com. Last edited: Mar 22, 2017. Just because there is an off switch on it this doesn't exclude it from the remit 7671. Apple Pay accepted in store. Field Offices handle scheduled interviews on other applications. Comlec Screwfix Select. Stay tuned for details on our Grand Opening. Terminal Capacity. 49 Inc Vat. Screwfix Community Forum. Contact PenFed by Phone. The coax aerial cable from the TV is then looped in to the transformer and out again to the aerial coax socket. Fit the FCU in the single then the double then carry on to the next double. Flex Outlet. Click & Collect in as little as a minute. Home Forums > Screwfix Community Forum > Electricians' Talk > FCU on 1. 80%>6. 60 days free credit available. As pump is in airing cupboard and you’ve got loft above, drop down a cable from the lighting circuit - obviously. Requires 35mm Back Box. After taking a look it appears that the existing outdoor socket is a spur itself, it is fed from an internal single socket (let’s call this the washing machine socket), which is fed by an internal FCU. What you have is basically a socket circuit which is fitted with a fused spur for use with the lighting circuit. Order British General IP66 13A Weatherproof Outdoor Switched Passive Fused Spur at Screwfix. Screwfix Community Forum. Installing spurs on a new circuit is sloppy. For Appliance Protection Circuits. Can't see any issue with having an FCU as part of the ring - the ones in the kitchen for fridge, washer etc are wired that way for example. We would like to. Just run a twin and earth from the supply side of the existing fcu to the new ones supply side ,and connect both lights to its load side. However, this is frowned upon as poor practice. Flex Outlet. Pay your way. Bazza, Aug 30, 2020 #9. Personally I would use 2. So the switched FCU will have a spur off the feed side That OK Switches will be labledunphased Screwfix Select For the short lengths involved just use 2. . Home Forums > Screwfix Community Forum > Electricians' Talk > FCU location on cooker hood install Discussion in ' Electricians' Talk ' started by BodgeTheBuilder , Jun 14, 2020 . to nearby 13amp fused isolation switch. Raised rounded profile with high gloss finish. Supplied with Replaceable 13A Fuse. Break into the ring and connect a 13amp fcu. com. They also provide limited information and services that supplement those we provide through our website and by phone. terrymac, Oct 6, 2019. So total 2250 watts. Get your bills sent directly to Democracy FCU online banking where you can view balances, statement information and pay them all in one convenient place. Simple process to unscrew and pull out and un plug, and then plug new. Home Forums > Screwfix Community Forum > Electricians' Talk > FCU for lights but not sockets on spur? Discussion in 'Electricians' Talk' started by Mr. paaulyb New Member. Need Help. White, moulded safety RCD protected fused connection unit that protects against the risk of a fatal electric shock. #4. My plan was to use 2. 842. Terminal Capacity. KIAB likes this. terrymac Screwfix Select. The UK’s. The only way I can see to do this is to remove the cable from the adjacent double socket feeding the spur and to replace it with a plug and flex to the spur instead. 5mm from one of the junction boxes into a FCU which I then fused down to 3 amps and I was then able to power my cctv cameras with a network switch and a. L1 is listed in the instructions as the live for the slave luminaire. Click on the gear wheel. Requires 25mm Back Box. Put one there specifically. - - - - Call 24/7 on: 03330 112 112 Call 24/7: 03330 112 112 Shop by. Products reviewed by the trade and home improvers. I have question regarding FCU unit. FREE next day delivery available, free collection in 1 minute. Discussion in 'Electricians' Talk' started by seneca2. 5mm2 twin and earth would connect between those terminals to the socket terminals. PayPal accepted online. 8811. 5mm², 2 x 4mm² or 1 x 6mm² cables. 5mm², 2 x 4mm² or 1 x. Need Help. Regards isolation they tell me it’s fine because the kitchen sockets are on an independent circuit on the new MCB so isolated there. Need to take account of distance etc etc. Hi all looking for some help please… I am in the process of converting my garage in to a room. Order online at Screwfix. A spur is to do with whether it is spurred off the wiring. There is no rule saying you can’t take two spurs from one point on the ring. Below is just a tiny selection of what you'll find at Screwfix Online:fitting a 4pole 32A rotary isolation switch to act as an isolator in a twin and earth wiring single phase 16A circuit leading to an invertor. adambaz Standard Member. com. 5 from the load side of this spur with a 13 amp fuse into the supply side of a spur in the right hand side of the box. Buy FCU Switches & Sockets at Screwfix. Remove fuse from the FCU suppling alarm panel. We'll that's what I've always used when I've done outside pond jobs. 2. Area manager for the bathroom company argued the toss about a FCU in zone 3 so i wanted all you good people to confirm my interpretation. The light switch, again, like the socket, had a FCU installed just before the switch. Wellwisher said: ↑. Over 40,000 products. My question is regarding the max Zs to be entered on the cert. 25 gallon Tank with lid. 2. View all: MK Fused Spurs. Buy FCU Switches & Sockets at Screwfix. . I see,you mean article 48234. Order MK Metal-Clad Plus 13A Switched Metal Clad Fused Spur & Flex Outlet with White Inserts at Screwfix. PayPal accepted online. Tony Goddard Screwfix Select. 5mm² cables. In my opinion it's no different to using 2. The electrics have been set up as follows… Existing double socket (on ring circuit) ————- spurred double socket ——— FCU 13A——— double socket ——— double socket——- double socket. 13A Switched Fused Connection Unit Spur White (2323D)Extend the ring by joining one of the legs in the back of the box, run this to the supply side of first fcu, supply side of second fcu and then back and terminate in the socket keeping the ring intact. is it good practice to use this to power the light via a FCU or am I going to have to rip up them boards Cheers Jim, Mar 31, 2005 #1. 5mm. I know that if on a fcu, you can spur from a spur but I can’t draw more than 13 amps. This little piece of 1. 4. seneca2, Jun 3, 2009 #2. Sunstate Federal Credit Union was chartered on Jan. 5 T&E that was used for immersion but now have combi boiler so outlet is not used. $500 minimum deposit. there’s no need. FCU Fused Spurs 0 Amp Rating Screwed or Screwless No. com. Nearest supply was a switched FCU (@3Amp) wired in downstairs ring main for cooker hood. You said you are not a spark. Tiling round FCU's is no different to tiling round sockets above the worktop though. joinerjohn1, Nov 6, 2011 #37. Once you are logged in, click or tap the 'More' tab in the bottom navigation menu. 00% min$500 12-month Liquid CD stayed at 5. Both the plug and the socket must be changed, do not plug any other item into the socket, or plug the boiler into any other socket as the damage will spread to other plugs and sockets as they will overheat. Without RCD. Choose from top trade brands. 6/5. Inside there are two earth connector fixings, and then on the top of the internal box are L1, L2 and L3 connector positions with T1, T2. Any possible reason for this set up. Garters said: ↑. Screwfix customers rate this product 4. At the moment FCU is wired to the existing single. 60 days free credit available. com. FCU: Switches & Sockets Profile Type: Raised Rounded: Terminal Capacity: Terminals accept 3 x 2. Discussion in 'Electricians' Talk' started by Mole80, May 13, 2023. CCX Plywood, 3/4 in x 4 ft x 8 ft - Southern Pine, Pressure Treated. 112, Dec 23, 2019. 60%>5. Similarly the pump will only pull 2. Delivery 7 days a week The UK’s leading retailer of trade tools and hardware. #12. Apple Pay accepted in store. So in a nutshell when i flick the sheds fcu it trips. 60 days free credit available. Delivery 7 days a week. Free next day delivery available. Was taught that way must be 30 years ago. That's two cables on the 'load' side of the FCU. 89Inc Vat. It then runs to 5 single sockets to power my led lights. Requires 25mm Back Box. Screwfix Community Forum. Buy FCU Fused Spurs at Screwfix. com. Requires 25mm Back Box. Once inside the shed put the swa inside a junction box and connect it to two 2. Worth mentioning that I've drilled a drain hole in the FCU. Assemble with other products into a modular front plate to create a grid. 5mm swa cable and have it coming out of the house and run along the wall into the shed. Have a redundant supply in bathroom cupboard, fed in 2. Home Forums > Screwfix Community Forum > Electricians' Talk > Double pole switch without FCU Discussion in ' Electricians' Talk ' started by DoItYoung , Feb 9, 2021 . 13A max. #14. PAGE 1 OF 7. spirits are real 2016 Screwfix Select. Delivery 7 days a week Choose from top trade brands. Need Help. consumer unit in shed. You are allowed 1 spur per socket on the ring. One is from the spur going into the FCU and the other going out to the 2gang socket. MK FCU Switches & Sockets (17 products) Categories Fused Spurs (17) Filters (1 applied) Clear all Brand British General (27) Crabtree (26) Essentials (4) LAP (33) MK (17). Join today and become part of the EFCU family. Apple Pay accepted in store. £ 1. 5 from the load side of this spur with a 13 amp fuse into the supply side of a spur in the right hand side of the box. 40m/sec Trip Speed. If you want to protect the fan wiring with a 3A FCU or whatever, you could put a cheaper 2 pole FCU on the live/neutral feed to the lighting, saves the expensive of having a 3 pole switch just for the fan. Discussion in ' Electricians' Talk ' started by DoItYoung, Feb 9, 2021 . Hi Everyone, I need some help. If I see any spurs wired in 1. Could I use this feed to supply further outside lights using a 2 gang switch. Buy LAP 13 A FCU Fused Spurs at Screwfix. 1. You can take one double or one single socket on one spur. Discussion in 'Electricians' Talk' started by dabhand, Jul 24, 2007. Delivery 7 days a week. Requires 35mm Back Box. Free next day delivery available. Top and bottom tracks included. Without RCD. The UK’s leading retailer of trade tools and hardware. Order online at Screwfix. Curiousity about one thing has led me to find something else. What is common practice is a FCU mounted 150-200mm from the side of the finished chimney with a 1mm T/E buried in the wall from the FCU (fusedd at 3A) at 90 degree's which then exits the plaster dead centre inside the chimney location which can then be junctioned box'd on to the flying lead inside the. ? thanks for any input / help lads. Order Crabtree Instinct 13A Switched Fused Spur & Flex Outlet with LED White at Screwfix. Buy Switches & Sockets at Screwfix. Sanitary Fixings Kits. Cables safely put in the wall or in trunking. com, Where the Trade Buys . Wellwisher, Sep 14, 2023. Tbh what you plan there is do-able but it's a bit of a weird way of doing it. With RCD. Posts 3, 4, 5, 10, & 16 are wrong. sparky Si-Fi Screwfix Select. Terminals accept 3 x 2. com. The plate is ok if a connection is needed there of course but the flex fitted to the towel rail usually plenty long enough to go through the wall and into the fcu. spirits are real 2016 Screwfix Select. for the cooker hood. Firstly, how did you identify you were taking a spur. Anyway,,,,,,,, as far as I know (I’m diy) the regs state that you can have a socket in a bathroom as long as it’s 3m away from a bath and/or shower and water jets. You could win a $500 grand prize, plus monthly gift cards!Screwfix, UK. As you have spured from the socket in 4. Marked "Fridge Freezer". 5 for any spurs. Look at the differences in opinion over one sodding fcu on a ring. Me as well, FCU,& feed running up to a 1G unswitched socket. Flex Outlet. Passive operation. Get the original bathroom fitters to come and move the fcu. Discussion in 'Electricians' Talk' started by touc, Feb 14, 2005. Screwfix Community Forum. 5mm swa. Buy online & collect in hundreds of stores in as little as 1 minute! Thousands of products. - - - - Call 24/7 on: 03330 112. The UK’s leading retailer of trade tools and hardware. com. diy_master said: ↑. Apple Pay accepted in store. com.